Mounting Demension

					Main Circuit Power Supply
					Single/three-phase 200V~240V +10%- 15%,50/60Hz
					Control Circuit Power Supply
					Single-phase 200V~240V +10%- 15%,50/60Hz
					Control Mode
					SVPWM、vector control
					Encoder Feedback
					17/20/23/24/25 bits absolute or incremental encoder
					Command Mode
					EtherCAT high-speed bus
					Communication Function
					Connect with computer (which has IMOTION software installed) via USB
					Regenerative Braking Resistor
					Built-in or external
					Dynamic Braking 
					Support
					Control Mode
					Profile position mode (PP)、 Cycle synchronous position mode (CSP)、 Homing mode (HM)
					Profile velocity mode (PV)、 Cycle synchronous velocity mode (CSV)
					Profile torque  mode (PT)、 Cycle synchronous torque  mode (CST)
						Hardware Protection
						Overvoltage、undervoltage、overcurrent、brake resistor overload、 drive overheating、encoder abnormality、etc
						Software Protection
						Memory failure、initialization failure、I/O allocation error、overspeed、overload、brake resistor overload、 position deviation excess、etc
						Fault Record
						Can record 14 faults and the latest 3 fault information